{"id":2418,"date":"2025-01-29T16:06:57","date_gmt":"2025-01-29T16:06:57","guid":{"rendered":"https:\/\/optics.carritech.com\/?p=2418"},"modified":"2025-01-30T15:10:59","modified_gmt":"2025-01-30T15:10:59","slug":"optical-transceiver-testing","status":"publish","type":"post","link":"https:\/\/optics.carritech.com\/fr\/optical-transceiver-testing\/","title":{"rendered":"Comment Carritech teste les \u00e9metteurs-r\u00e9cepteurs optiques"},"content":{"rendered":"<p class=\"wp-block-paragraph\">At Carritech, we pride ourselves on delivering <a href=\"https:\/\/optics.carritech.com\/fr\/optical-transceivers\/\">high-quality optical transceivers<\/a> that meet the strict performance and reliability standards required for telecommunications networks. Our rigorous testing process ensures that every optical transceiver we supply is fully functional, meets industry specifications, and is ready for deployment in critical infrastructure. In this article, we outline our comprehensive testing procedures and the steps we take to guarantee quality and performance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-our-testing-process\">Our Testing Process<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At Carritech, we employ a multi-step approach to test our optical transceivers. Each transceiver undergoes a stringent evaluation process that includes compatibility checks, optical performance measurements, and stress testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-visual-inspection-and-end-face-testing\">1. Visual Inspection and End Face Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before conducting any performance testing, we perform a thorough visual inspection of each transceiver. We examine the physical structure to identify any defects or damages and verify the accuracy of labeling and serial numbers. Additionally, we inspect the end face to ensure it is clean and free from contamination, which enhances signal stability, transmission quality, and longevity.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-eeprom-and-compatibility-testing\">2. EEPROM and Compatibility Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Each transceiver&#8217;s EEPROM (Electrically Erasable Programmable Read-Only Memory) is read and verified to ensure correct programming. This step checks vendor compatibility, wavelength specifications, and transmission power and receiver sensitivity parameters. By doing so, we confirm that the transceiver will function correctly with different networking equipment, including routers, switches, and multiplexers.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-optical-performance-testing\">3. Optical Performance Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To guarantee signal integrity and reliability, we assess key optical performance indicators. We analyze the eye diagram to evaluate the quality of the transmitted signal and test the receiving sensitivity to ensure the transceiver can accurately detect weak signals. We also measure the extinction ratio to verify the effectiveness of signal modulation, while monitoring power consumption to ensure light-emitting and light-receiving power, voltage, and current remain stable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-optical-power-and-wavelength-accuracy-testing\">4. Optical Power and Wavelength Accuracy Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Using precision optical test equipment, we validate that each transceiver operates within its specified power levels and wavelength range. We measure the transmit optical power to confirm that it emits the correct output power for reliable transmission. Additionally, we test the receiver sensitivity to verify its ability to interpret signals correctly at low power levels. <\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-traffic-and-bit-error-rate-ber-testing\">5. Traffic and Bit Error Rate (BER) Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To assess network performance, we conduct traffic and bit error rate (BER) testing. We analyze packet loss rates to confirm that data is transmitted without unexpected drops or corruption. Loopback tests are used to send and receive signals within the transceiver, allowing us to detect potential errors. We evaluate traffic patterns based on industry standards to measure data transmission accuracy and conduct extended BER testing over a prolonged period to identify any intermittent performance issues.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-6-temperature-and-environmental-stress-testing\">6. Temperature and Environmental Stress Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Since 10G DWDM SFP+ transceivers are often deployed in environments with fluctuating temperatures, we conduct rigorous stress testing to simulate real-world conditions. We expose transceivers to extreme temperature ranges, from -40\u00b0C to 85\u00b0C, to ensure they can function reliably under harsh conditions. Thermal cycling tests are performed to assess their resilience to temperature fluctuations, while power cycling tests verify their stability and startup performance after repeated power on-off cycles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-7-final-functional-testing-and-certification\">7. Final Functional Testing and Certification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Once a transceiver has successfully passed all previous tests, it undergoes a final functional test in a live network environment or testbed setup. We verify its seamless integration with networking equipment, confirm stable data transmission over extended periods, and ensure compliance with industry standards, including the Multi-Source Agreement (MSA) and IEEE 802.3ae. Only after meeting all these criteria is a transceiver certified as ready for deployment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-conclusion\">Conclusion<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Carritech&#8217;s rigorous testing process ensures that every 10G DWDM SFP+ optical transceiver we supply is reliable, high-performing, and ready for use in demanding network environments. Our commitment to quality control and testing helps our customers maintain robust and efficient telecommunications networks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>If you require tested and certified optical transceivers, <a href=\"https:\/\/optics.carritech.com\/fr\/contact-us\/\">contact Carritech today<\/a> to learn more about our products and services.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Chez Carritech, nous sommes fiers de fournir des \u00e9metteurs-r\u00e9cepteurs optiques de haute qualit\u00e9 qui r\u00e9pondent aux normes strictes de performance et de fiabilit\u00e9 requises pour les r\u00e9seaux de t\u00e9l\u00e9communications. Notre processus de test rigoureux garantit que chaque \u00e9metteur-r\u00e9cepteur optique que nous fournissons est enti\u00e8rement fonctionnel, conforme aux sp\u00e9cifications de l'industrie et pr\u00eat \u00e0 \u00eatre d\u00e9ploy\u00e9 dans les infrastructures critiques. Dans cet article, nous d\u00e9crivons nos tests complets [...]<\/p>","protected":false},"author":1,"featured_media":2419,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[175,176,177,178,179,180,173,183,184,186,187,188,189,190,191,205,203,171,202,204,172,182,185],"tags":[],"class_list":["post-2418","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-1-25g-bidi-sfp","category-1-25g-csfp","category-1-25g-cwdm","category-1-25g-duplex-sfp","category-1-25g-dwdm-sfp","category-100m-bidi-sfp","category-100m-duplex-sfp","category-10g-bidi-sfp-sfp-optical-transceivers-2","category-10g-bidi-xfp","category-10g-cwdm-xfp","category-10g-duplex-sfp","category-10g-duplex-xfp","category-10g-tunable-dwdm-sfp","category-10g-tunable-dwdm-xfp","category-16g-fiber-channel-sfp","category-400g-qsfp-dd","category-800g-osfp","category-optical-transceivers","category-osfp","category-qsfp-dd","category-sfp","category-sfp-optical-transceivers-2","category-xfp"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Optical Transceiver Testing | How It Works | Carritech Optics<\/title>\n<meta name=\"description\" content=\"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/optics.carritech.com\/fr\/optical-transceiver-testing\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Carritech Tests Optical Transceivers\" \/>\n<meta property=\"og:description\" content=\"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/optics.carritech.com\/fr\/optical-transceiver-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Carritech Optics\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-29T16:06:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-30T15:10:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1435\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/optics.carritech.com\/#\/schema\/person\/00fd2c4f332d754325cad053cd4a8a9d\"},\"headline\":\"How Carritech Tests Optical Transceivers\",\"datePublished\":\"2025-01-29T16:06:57+00:00\",\"dateModified\":\"2025-01-30T15:10:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/\"},\"wordCount\":642,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/optics.carritech.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg\",\"articleSection\":[\"1.25G BIDI SFP\",\"1.25G CSFP\",\"1.25G CWDM\",\"1.25G Duplex SFP\",\"1.25G DWDM SFP\",\"100M BIDI SFP\",\"100M Duplex SFP\",\"10G BiDi SFP+\",\"10G BIDI XFP\",\"10G CWDM XFP\",\"10G Duplex SFP+\",\"10G Duplex XFP\",\"10G Tunable DWDM SFP+\",\"10G Tunable DWDM XFP\",\"16G FIBER CHANNEL SFP+\",\"400G QSFP-DD\",\"800G OSFP\",\"Optical Transceivers\",\"OSFP\",\"QSFP-DD\",\"SFP\",\"SFP+\",\"XFP\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/\",\"url\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/\",\"name\":\"Optical Transceiver Testing | How It Works | Carritech Optics\",\"isPartOf\":{\"@id\":\"https:\/\/optics.carritech.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg\",\"datePublished\":\"2025-01-29T16:06:57+00:00\",\"dateModified\":\"2025-01-30T15:10:59+00:00\",\"description\":\"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.\",\"breadcrumb\":{\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage\",\"url\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg\",\"contentUrl\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg\",\"width\":2560,\"height\":1435,\"caption\":\"optical-transceiver-testing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/optics.carritech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Carritech Tests Optical Transceivers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/optics.carritech.com\/#website\",\"url\":\"https:\/\/optics.carritech.com\/\",\"name\":\"Carritech Optics\",\"description\":\"High Quality Optical Transceivers\",\"publisher\":{\"@id\":\"https:\/\/optics.carritech.com\/#organization\"},\"alternateName\":\"Carritech Optics\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/optics.carritech.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/optics.carritech.com\/#organization\",\"name\":\"Carritech Optics\",\"url\":\"https:\/\/optics.carritech.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/optics.carritech.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2024\/11\/Carritech-optics.png\",\"contentUrl\":\"https:\/\/optics.carritech.com\/wp-content\/uploads\/2024\/11\/Carritech-optics.png\",\"width\":2048,\"height\":681,\"caption\":\"Carritech Optics\"},\"image\":{\"@id\":\"https:\/\/optics.carritech.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/optics.carritech.com\/#\/schema\/person\/00fd2c4f332d754325cad053cd4a8a9d\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/optics.carritech.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1ab96350f6268bdc63743a0e3954a16bbe6c9e815fe11a0cde9e8ae7591816b5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1ab96350f6268bdc63743a0e3954a16bbe6c9e815fe11a0cde9e8ae7591816b5?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/optics.carritech.com\"],\"url\":\"https:\/\/optics.carritech.com\/fr\/author\/youbiquity\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Optical Transceiver Testing | How It Works | Carritech Optics","description":"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/optics.carritech.com\/fr\/optical-transceiver-testing\/","og_locale":"fr_FR","og_type":"article","og_title":"How Carritech Tests Optical Transceivers","og_description":"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.","og_url":"https:\/\/optics.carritech.com\/fr\/optical-transceiver-testing\/","og_site_name":"Carritech Optics","article_published_time":"2025-01-29T16:06:57+00:00","article_modified_time":"2025-01-30T15:10:59+00:00","og_image":[{"width":2560,"height":1435,"url":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"admin","Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#article","isPartOf":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/"},"author":{"name":"admin","@id":"https:\/\/optics.carritech.com\/#\/schema\/person\/00fd2c4f332d754325cad053cd4a8a9d"},"headline":"How Carritech Tests Optical Transceivers","datePublished":"2025-01-29T16:06:57+00:00","dateModified":"2025-01-30T15:10:59+00:00","mainEntityOfPage":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/"},"wordCount":642,"commentCount":0,"publisher":{"@id":"https:\/\/optics.carritech.com\/#organization"},"image":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg","articleSection":["1.25G BIDI SFP","1.25G CSFP","1.25G CWDM","1.25G Duplex SFP","1.25G DWDM SFP","100M BIDI SFP","100M Duplex SFP","10G BiDi SFP+","10G BIDI XFP","10G CWDM XFP","10G Duplex SFP+","10G Duplex XFP","10G Tunable DWDM SFP+","10G Tunable DWDM XFP","16G FIBER CHANNEL SFP+","400G QSFP-DD","800G OSFP","Optical Transceivers","OSFP","QSFP-DD","SFP","SFP+","XFP"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/optics.carritech.com\/optical-transceiver-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/","url":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/","name":"Optical Transceiver Testing | How It Works | Carritech Optics","isPartOf":{"@id":"https:\/\/optics.carritech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage"},"image":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg","datePublished":"2025-01-29T16:06:57+00:00","dateModified":"2025-01-30T15:10:59+00:00","description":"Our optical transceiver testing process makes sure each one we provide works well, meet industry standards and are ready for use.","breadcrumb":{"@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/optics.carritech.com\/optical-transceiver-testing\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#primaryimage","url":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg","contentUrl":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2025\/01\/AdobeStock_1127419403-scaled.jpeg","width":2560,"height":1435,"caption":"optical-transceiver-testing"},{"@type":"BreadcrumbList","@id":"https:\/\/optics.carritech.com\/optical-transceiver-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/optics.carritech.com\/"},{"@type":"ListItem","position":2,"name":"How Carritech Tests Optical Transceivers"}]},{"@type":"WebSite","@id":"https:\/\/optics.carritech.com\/#website","url":"https:\/\/optics.carritech.com\/","name":"Carritech Optics","description":"High Quality Optical Transceivers","publisher":{"@id":"https:\/\/optics.carritech.com\/#organization"},"alternateName":"Carritech Optics","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/optics.carritech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/optics.carritech.com\/#organization","name":"Carritech Optics","url":"https:\/\/optics.carritech.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/optics.carritech.com\/#\/schema\/logo\/image\/","url":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2024\/11\/Carritech-optics.png","contentUrl":"https:\/\/optics.carritech.com\/wp-content\/uploads\/2024\/11\/Carritech-optics.png","width":2048,"height":681,"caption":"Carritech Optics"},"image":{"@id":"https:\/\/optics.carritech.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/optics.carritech.com\/#\/schema\/person\/00fd2c4f332d754325cad053cd4a8a9d","name":"admin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/optics.carritech.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1ab96350f6268bdc63743a0e3954a16bbe6c9e815fe11a0cde9e8ae7591816b5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1ab96350f6268bdc63743a0e3954a16bbe6c9e815fe11a0cde9e8ae7591816b5?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/optics.carritech.com"],"url":"https:\/\/optics.carritech.com\/fr\/author\/youbiquity\/"}]}},"_links":{"self":[{"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/posts\/2418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/comments?post=2418"}],"version-history":[{"count":2,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/posts\/2418\/revisions"}],"predecessor-version":[{"id":2421,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/posts\/2418\/revisions\/2421"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/media\/2419"}],"wp:attachment":[{"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/media?parent=2418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/categories?post=2418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/optics.carritech.com\/fr\/wp-json\/wp\/v2\/tags?post=2418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}